EasyManua.ls Logo

INVT GD200-037G/045P-4 - Page 155

INVT GD200-037G/045P-4
266 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Goodrive200 inverters Basic operation instruction
154
Function
code
Name Detailed instruction of parameters
Default
value
P01.03
The braking current before
starting
0.0~100.0% 0.0%
P01.04
The braking time before
starting
0.00~50.00s 0.00s
P01.05 ACC/DEC selection
0:Linear type
1:Reserved
0
P01.08 Stop mode
0:Decelerate to stop
1:Coast to stop
0
P01.09
Starting frequency of DC
braking
0.00Hz~P00.03(the Max. frequency) 0.00Hz
P01.10
Waiting time before DC
braking
0.00~50.00s 0.00s
P01.11 DC braking current 0.0~150.0% 0.0%
P01.12 DC braking time 0.00~50.00s 0.00s
P01.13
Dead time of FWD/REV
rotation
0.0~3600.0s 0.0s
P01.14
Shifting between
FWD/REV rotation
0:Switch after 0 frequency
1:Switch after the starting frequency
2:Switch after the stopping speed
0
P01.15 Stopping speed 0.00~100.00Hz 0.50 Hz
P01.19
Action selection
(operation
frequency<lower
frequency limit and valid
when the lower limit >0)
0: Run at the lower-limit frequency
1: Stop
2: Hibernation
0
P01.20
Hibernation restore delay
time
0.0~3600.0s(valid when P01.15=2) 0.0s
P01.21 Restart after power off
0: Disable
1: Enable
0
P01.22
The waiting time of restart
after power off
0.0~3600.0s(valid when P01.21=1) 1.0s