Goodrive200 inverters Basic operation instruction
175
Function
code
Name Detailed instruction of parameters
Default
value
BIT7:S8 virtual terminal
BIT8:HDI virtual terminal
P05.13
Terminals control running
mode
0:2-wire control 1
1:2-wire control 2
2:3-wire control 1
3:3-wire control 2
0
P05.14
S1 terminal switching-
on
delay time
0.000~50.000s 0.000s
P05.15
S1
terminal switching-off
delay time
0.000~50.000s 0.000s
P05.16
S2 terminal switching-
on
delay time
0.000~50.000s 0.000s
P05.17
S2
terminal switching-off
delay time
0.000~50.000s 0.000s
P05.18
S3 terminal switching-
on
delay time
0.000~50.000s 0.000s
P05.19
S3
terminal switching-off
delay time
0.000~50.000s 0.000s
P05.20
S4 terminal switching-
on
delay time
0.000~50.000s 0.000s
P05.21
S4
terminal switching-off
delay time
0.000~50.000s 0.000s
P05.22
S5
terminal switching-on
delay time
0.000~50.000s 0.000s
P05.23
S5
terminal switching-off
delay time
0.000~50.000s 0.000s