Goodrive200 inverters Basic operation instruction
174
Function
code
Name Detailed instruction of parameters
Default
value
27:Traverse reset
(return to the center frequency)
28:Counter reset
29: Torque control prohibition
30:ACC/DEC prohibition
31:Counter trigger
32:Length reset
33:Cancel the frequency change setting
temporally
34:DC brake
35: Reserved
36:Shift the command to the keypad
37:Shift the command to the terminals
38:Shift the command to the
communication
39: Pre-exciting command
40:Clear the power
41:Keep the power
42~60:Reserved
61: PID pole switching
42~63: Reserved
P05.10
Polarity selection of the
input terminals
0x000~0x1FF 0x000
P05.11 ON-OFF filter time 0.000~1.000s 0.010s
P05.12 Virtual terminals setting
0x000~0x1FF(0: Disabled, 1:Enabled )
BIT0:S1 virtual terminal
BIT1:S2 virtual terminal
BIT2:S3 virtual terminal
BIT3:S4 virtual terminal
BIT4:S5 virtual terminal
BIT5:S6 virtual terminal
BIT6:S7 virtual terminal
0