Goodrive270 series VFD for fan and pump Function parameter list
-148-
Function
code
Name Description Default
Modify
frequency of AM 1) or
P04.05±P02.16 (Rated
frequency of SM 1)
P04.08
setting range: 0.0%±
110.0% (of the rated
voltage of motor 1)
P04.09
V/F slip
compensation gain
of motor 1
Used to compensate for the motor rotating speed
change caused by load change in the space
voltage vector mode, and thus improve the
rigidity of the mechanical characteristics of the
motor. You need to calculate the rate
d slip
frequency of the motor as follows:
f=f
b
-n*p/60
Of which, f
b
is the rated frequency of the motor,
corresponding to function code
P02.02. n is the
rated rotating speed of the motor, corresponding
to function code
P02.03. p is the number of pole
pairs of the motor. 100.0% corresponds to the
rated slip frequency
f of motor 1.
Setting range: 0.0±200.0%
0.0% ƻ
P04.10
Low-frequency
oscillation control
factor of motor 1
In space voltage vector control mode, the motor,
especially the large
-power motor, may
experience current oscillation at certain
frequencies, which may cause unstable motor
running, or even VFD overcurrent. You can
adjust the two function codes properly to
eliminate such phenomenon.
P04.10
setting range: 0±100
P04.11
setting range: 0±100
P04.12
setting range: 0.00Hz±P00.03 (Max.
output frequency)
10 ƻ
P04.11
High-frequency
oscillation control
factor of motor 1
10 ƻ
P04.12
Oscillation control
threshold of motor 1
30.00Hz ƻ
P04.13
V/F curve setting of
motor 2
This group of function code defines the V/F curve
of motor 2 to meet the needs of differe
nt loads.
0: Straight
-line V/F curve
1: Multi
-point V/F curve
2: Torque
-down V/F curve (power of 1.3)
3: Torque
-down V/F curve (power of 1.7)
4: Torque
-down V/F curve (power of 2.0)
5: Customized V/F curve (V/F separation)
Note: Refer to the description for P04.00.