SYSTem Commands
Copyright © ITECH Electronic Co., Ltd. 19
Example
SYST:LOC
SYSTem:RWLock
This command locks the power supply in remote control mode. When this
command is executed, pressing the LOCAL button does not switch the instrument
to local control mode.
Syntax
SYSTem:RWLock
Arguments
None
Reset value
Not applicable
Example
SYST:RWL
SYSTem:BEEPer:IMMediate
This command tests the beeper function of the power supply. If it passes the test,
a beep is issued.
Syntax
SYSTem:BEEPer:IMMediate
Arguments
None
Reset value
Not applicable
Example
SYST:BEEP:IMM
SYSTem:BEEPer[:STATe] <CPD>
This command enables or disables the beeper function of the power supply.
Syntax
SYSTem:BEEPer[:STATe] <CPD>
Arguments
OFF|ON