Routine Maintenance
Greasing
128 128
9811-3400-4
Filling the Reservoir
It is essential that the correct grease is used in this system.
Refer to Fluid, Lubricants and Capacities.
1 Remove the dust cap from the filler coupling A.
2 Carefully clean the area around the filler coupling and
the coupling on the filler hose.
3 Attach the filler hose to the coupling A.
4 Fill the reservoir B until the top of the follower plate C
(the plate on top of the grease) is level with the
maximum level mark.
5 Remove the filler hose, clean the coupling and refit
the dust cap.
Note: Any air introduced during filling will exit via the
reservoir vent. If large amounts of air are present, carry out
a continuous greasing cycle for one minute.
807200-1
Fig 73.