Routine Maintenance
Greasing
130 130
9811-3400-4
Replacing the Fill Point Filter
1 Clean the area around the filler coupling E.
2 Remove the filler coupling E from the filter G.
3 Loosen locknut F.
4 Remove filter G.
Note: Grease may flow from the housing when the filter is
removed.
!MCAUTION
Pressurised grease may flow from the filter housing as
the filter is loosened.
4-3-5-6
5 Screw the new filter into the filter housing, hand-tight
only, until the O ring contacts the filter housing.
6 Tighten locknut F to 15Nm (133lbf in).
7 Refit the filler coupling.
807210-1