FX-3R Maintenance Guide
2-10
2-3. Replacing the Laser Sensor (LNC60)
After the LNC60 has been replaced, it is absolutely necessary to re-input the MS parameters related
to the laser. (See section 2-7.)
1) Disconnect the connectors (encoder and
IEEE1394) and remove the mounting screws
c and d (3 pcs.) to detach the LNC60.
Rev. 1.00
2) Reassemble the components in the reverse
order of disassembly.
Before mounting the components, remove
Loctite sticking to the sensor bracket as much as
possible.
When attaching the sensor, insert the sensor pin
into the positioning hole of the bracket first. Then
fix the sensor.
Apply Loctite 242 to the sensor mounting screws
c and d and tighten them with a tightening
torque of 2.6 Nm.
After the LNC60 has been replaced, clean the
laser beam window of the LNC60 with a clean
cloth rag.
c SL6041692TN
SEMS cap bolt with
washer M4×16
d SM6041402TN
SEMS cap bolt M4×14
40045547
LNC60
Figure 2-3-1 Laser Sensor
Assembling Position