FX-3R Maintenance Guide
4-9
4-8. Readjustment After Replacement of OCC Unit
{: Mandatory U: Check : Unnecessary
: Optional
Table 4-8-1 List of Readjustment Items after Replacement
OCC lens
assembly
OCC light
assembly
Light board
assembly
Lens filter
OCC focus adjustment {
Filter adjustment U {
{
Adjustment of OCC light quantity U { { {
Common mark adjustment {
X-beam parallelism check {
OCC offset {
CAL block offset {
CAL piece holder offset {
Head offset {
HMS offset {
BMR offset
{
ATC offset U
AWC offset U
Pick-Up reference position offset U
CVS offset
U
SOT inspect unit
U
Vacuum offset U
General mounting offset {
Input the MS parameters from the top in order.
CAUTION
To prevent any personal injury, do not put your hand inside the
machine or your face or head close to the machine during operation
of the touch panel and/or HOD.