EasyManuals Logo

Juniper EX9214 Hardware Guide

Juniper EX9214
385 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #181 background imageLoading...
Page #181 background image
Table 58: Parts Required for Connecng an EX Series Switch to Earth Ground
(Connued)
Switch Earthing
Terminal
Locaon
Grounding
Cable
Requirements
Grounding Lug
Specicaons
Screws and
Washers
Addional
Informaon
EX8216 Two earthing
terminals:
Le side
of the
chassis
Rear
panel of
the
chassis
NOTE: You
must use
only one of
the two
protecve
earthing
terminals.
2 AWG
(33.6 mm²),
minimum 90° C
wire, or as
permied by
the local code
Panduit LCD2-14A-
Q or equivalent
—provided
Two ¼ -20 x
0.5 in.
screws with
#¼” split-
washer
—provided
Two #¼” at
washers—
provided
EX9204,
EX9208,
and
EX9214
Rear panel of
the chassis
One 6 AWG
(13.3 mm²),
minimum 90° C
wire, or one
that complies
with the local
code
Thomas& Bes
LCN6-14 or
equivalent—
provided
Two ¼ -20
x 0.5 in.
screws with
#¼” split-
washer—
provided
Two #¼” at
washers—
provided
See Grounding
Cable and Lug
Specicaons for
EX9200 Switches.
170

Table of Contents

Other manuals for Juniper EX9214

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper EX9214 and is the answer not in the manual?

Juniper EX9214 Specifications

General IconGeneral
BrandJuniper
ModelEX9214
CategorySwitch
LanguageEnglish