Table 61: Chassis Component Alarm Condions on EX9200 Switches
(Connued)
Chassis
Component
Alarm Condion Alarm
Severity
Remedy
Hot swapping Too many hot-swap interrupts
are occurring. This message
generally indicates that a
hardware component that plugs
into the switch’s backplane
from the front (generally, an
FPC) is broken.
Major (red) Replace the failed components.
Power supplies A power supply has been
removed from the chassis.
Minor
(yellow)
Install a power supply in the empty slot.
A power supply has a high
temperature.
Major (red) Replace the failed power supply or power
entry module.
A power supply input has
failed.
Major (red) Check power supply input connecon.
A power supply output has
failed.
Major (red) Check power supply output connecon.
A power supply has failed. Major (red) Replace the failed power supply.
Invalid AC power supply
conguraon.
Major (red) When two AC power supplies are installed,
install one power supply in an odd-
numbered slot and the other power supply
in an even-numbered slot.
Invalid DC power supply
conguraon.
Major (red) When two DC power supplies are installed,
install one power supply in an odd-
numbered slot and the other power supply
in an even-numbered slot.
AC and DC power supplies are
installed.
Major (red) Do not mix AC and DC power supplies.
295