Table 61: Chassis Component Alarm Condions on EX9200 Switches
(Connued)
Chassis
Component
Alarm Condion Alarm
Severity
Remedy
Hot swapping Too many hot-swap interrupts
are occurring. This message
generally indicates that a
hardware component that plugs
into the switch’s backplane
from the front (generally, an
FPC) is broken.
Major (red) Replace the failed components.
Power supplies A power supply has been
removed from the chassis.
Minor
(yellow)
Install a power supply in the empty slot.
A power supply has a high
temperature.
Major (red) Replace the failed power supply or power
entry module.
A power supply input has
failed.
Major (red) Check power supply input connecon.
A power supply output has
failed.
Major (red) Check power supply output connecon.
A power supply has failed. Major (red) Replace the failed power supply.
Invalid AC power supply
conguraon.
Major (red) When two AC power supplies are installed,
install one power supply in an odd-
numbered slot and the other power supply
in an even-numbered slot.
Invalid DC power supply
conguraon.
Major (red) When two DC power supplies are installed,
install one power supply in an odd-
numbered slot and the other power supply
in an even-numbered slot.
AC and DC power supplies are
installed.
Major (red) Do not mix AC and DC power supplies.