Table 61: Chassis Component Alarm Condions on EX9200 Switches
(Connued)
Chassis
Component
Alarm Condion Alarm
Severity
Remedy
Inadequate number of power
supplies.
Major (red) Install an addional power supply.
Switch Fabric
Module (SF
module)
An SF module has been
removed.
Minor
(yellow)
Install an SF module in the empty slot.
An SF module has failed. Major (red) Replace the failed SF module.
Roung Engine Excessive framing errors on
console port.
An excessive framing error
alarm is triggered when the
default framing error threshold
of 20 errors per second on a
serial port is exceeded.
A faulty serial console port
cable might be connected to
the device.
Minor
(yellow)
Replace the serial cable connected to the
device.
If the cable is replaced and no excessive
framing errors are detected within 5
minutes from the last detected framing
error, the alarm is cleared automacally.
Error in reading or wring hard
disk.
Minor
(yellow)
Reformat the hard disk and install the
bootable image. If this fails, replace the
failed Roung Engine.
Error in reading or wring
CompactFlash card.
Minor
(yellow)
Reformat the CompactFlash card and install
the bootable image. If this fails, replace the
failed Roung Engine.
System booted from the default
backup Roung Engine. If you
manually switched primary role,
ignore this alarm condion.
Minor
(yellow)
Install the bootable image on the default
primary Roung Engine. If this fails, replace
the failed Roung Engine.
296