Table 61: Chassis Component Alarm Condions on EX9200 Switches
(Connued)
Chassis
Component
Alarm Condion Alarm
Severity
Remedy
Inadequate number of power
supplies.
Major (red) Install an addional power supply.
Switch Fabric
Module (SF
module)
An SF module has been
removed.
Minor
(yellow)
Install an SF module in the empty slot.
An SF module has failed. Major (red) Replace the failed SF module.
Roung Engine Excessive framing errors on
console port.
An excessive framing error
alarm is triggered when the
default framing error threshold
of 20 errors per second on a
serial port is exceeded.
A faulty serial console port
cable might be connected to
the device.
Minor
(yellow)
Replace the serial cable connected to the
device.
If the cable is replaced and no excessive
framing errors are detected within 5
minutes from the last detected framing
error, the alarm is cleared automacally.
Error in reading or wring hard
disk.
Minor
(yellow)
Reformat the hard disk and install the
bootable image. If this fails, replace the
failed Roung Engine.
Error in reading or wring
CompactFlash card.
Minor
(yellow)
Reformat the CompactFlash card and install
the bootable image. If this fails, replace the
failed Roung Engine.
System booted from the default
backup Roung Engine. If you
manually switched primary role,
ignore this alarm condion.
Minor
(yellow)
Install the bootable image on the default
primary Roung Engine. If this fails, replace
the failed Roung Engine.
296