Changing the Reset Config Button Behavior on the SRX100 Services Gateway
You can change the default operation of the Reset Config button by limiting how the
button resets the services gateway:
To prevent the Reset Config button from setting the device to the factory default
configuration and deleting all other configurations, enter the following command:
user@host# set chassis config-button no-clear
You can still press and quickly release the button to reset it to the rescue
configuration.
To prevent the Reset Config button from setting the device to the rescue
configuration, enter the following command:
user@host# set chassis config-button no-rescue
You can still press and hold the button for 15 seconds or more to reset the
gateway to the factory defaults.
To disable the button and prevent the device from resetting to either
configuration, use the following command:
user@host# set chassis config-button no-clear no-rescue
The no-rescue option prevents the Reset Config button from loading the rescue
configuration. The no-clear option prevents the Reset Config button from deleting all
configurations on the services gateway.
To return the function of the Reset Config button to its default behavior, remove the
config-button statement from the device configuration.
Related Topics Using the Reset Config Button on the SRX100 Services Gateway on page 85
Monitoring the SRX100 Services Gateway Chassis Using the CLI on page 79
Monitoring the SRX100 Services Gateway Components Using LEDs on page 81
Monitoring the SRX100 Services Gateway Using Chassis Alarm Conditions on
page 83
Monitoring the SRX100 Services Gateway Power System on page 84
Juniper Networks Technical Assistance Center on page 87
Juniper Networks Technical Assistance Center
This topic includes the following section:
Juniper Networks Technical Assistance Center on page 87
86 Changing the Reset Config Button Behavior on the SRX100 Services Gateway
SRX100 Services Gateway Hardware Guide

Table of Contents

Other manuals for Juniper SRX100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper SRX100 and is the answer not in the manual?

Juniper SRX100 Specifications

General IconGeneral
Routing protocolsBGP, IS-IS, MPLS, OSPF
Switching protocolsVLAN 802.1Q, 802.3ad/LACP, STP
Supported network protocolsIPv4, IPv6, CLNS
Firewall securityYes
Security algorithms3DES, DES
Authentication methodRADIUS, RSA SecureID, LDAP
VPN supportIPsec VPN
Data transfer rate0.1 Gbit/s
Input voltage100 - 240 V
Input frequency50/60 Hz
Heat dissipation35 BTU/h
Power requirements100-240, 50/60
Power over Ethernet (PoE)No
Power consumption (typical)30 W
SafetyUL 60950-1, CSA 60950-1, AS / NZS 60950-1, AS / NZS 60950-1, CB Scheme, EN 60950-1
CertificationFCC Class B ICES class B AS / NZS CISPR22 Class B AS / NZS CISPR22 Class B VCCI Class B EN 55022 Class B, EN 300386
Mounting typeRack mounting
Internal memory1024 MB
Storage temperature (T-T)-20 - 70 °C
Operating temperature (T-T)0 - 40 °C
Weight and Dimensions IconWeight and Dimensions
Weight1100 g
Dimensions (WxDxH)216 x 147 x 36 mm

Related product manuals