To ground the device:
1. Connect the grounding cable to a proper earth ground.
2. Verify that a licensed electrician has attached the cable lug to the grounding cable.
3. Place the grounding cable lug over the grounding point on the upper rear of the chassis.
4. Secure the grounding cable lug to the grounding point with the screw. Apply between
6 in.-lb (0.67 Nm) and 8 in.-lb (0.9 Nm) of torque to the screws.
5. Dress the grounding cable and verify that it does not touch or block access to the
services gateway components and that it does not cause create a tripping hazard.
NOTE: The device shouldbe permanentlyconnected to groundduring normal
operation.
Related
Documentation
Connecting the SRX210 Services Gateway to the Power Supply on page 105
Connecting and Organizing Interface Cables to the SRX210 Services Gateway on
page 106
SRX210 Services Gateway Grounding Specifications on page 69
Powering On and Powering Off the SRX210 Services Gateway on page 109
SRX210 Services Gateway General Safety Guidelines and Warnings on page 47
Powering On and Powering Off the SRX210 Services Gateway
This topic includes the following sections:
Powering On the SRX210 Services Gateway on page 109
Powering Off the SRX210 Services Gateway on page 110
Resetting the SRX210 Services Gateway on page 111
Powering On the SRX210 Services Gateway
To power on the services gateway:
1. Ensure that you have connected the power supply to the device.
2. Insert the plug of the power supply adapter into an AC power source receptacle.
3. Turn on the power to the AC power receptacle.
The device starts automatically as the power supply completes its startup sequence.
The Power LED lights up during startup and remains on steadily when the device is
operating normally.
109Copyright © 2012, Juniper Networks, Inc.