EasyManua.ls Logo

Juniper SRX210 Series - Chapter 8 Power Guidelines, Requirements, and Specifications; SRX210 Services Gateway Site Electrical Wiring Guidelines; Table 20: Site Electrical Wiring Guidelines for the Services Gateway

Juniper SRX210 Series
188 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CHAPTER 8
Power Guidelines, Requirements, and
Specifications
SRX210 Services Gateway Site Electrical Wiring Guidelines on page 67
SRX210 Services Gateway Power Specifications and Requirements on page 68
SRX210 Services Gateway Grounding Specifications on page 69
SRX210 Services Gateway Site Electrical Wiring Guidelines
Table 20 on page 67 describes the factors you must consider while planning the electrical
wiring for the services gateway at your site.
CAUTION: It is particularly important to provide a properly grounded and
shielded environment and to use electrical surge-suppression devices.
CAUTION: For devices with AC power supplies, an external surge protective
device (SPD) must be used at the AC power source.
Table 20: Site Electrical Wiring Guidelines for the Services Gateway
GuidelineSite Wiring Factor
To ensure that signaling functions optimally:
Install wires correctly.
Improperly installed wires can emit radio interference.
Do not exceed the recommended distances or pass wires
between buildings.
The potential for damage from lightning strikes increases if wires
exceed recommended distances or if wires pass between
buildings.
Shield all conductors.
The electromagnetic pulse (EMP) caused by lightning can
damage unshielded conductors and destroy electronic devices.
Signaling Limitations
67Copyright © 2012, Juniper Networks, Inc.

Table of Contents

Related product manuals