Load Edge Series
60 Operations for Load Mode
(5) Setting parameters.
The following figures show each parameter and operation.
*Set CC1 and CC2 only and skipped other settings.
[Auto] [Single]
[Continuous operation] Run Loop [Single operation] RUN-SINGLE
Fig. 5-12-4 Parameters and operation
Setting screen shown as follow.
Fig. 5-12-5 Setting screen
When turned rotary encoder, under bar will shift accordingly.
The parameters can be entered by the ten key or rotary encoder if pressed “ENT” where entering
new parameters. When pressed “ENT”, color of the selected item reversed.
Pressing “ENT” again disables the input by the rotary encoder.
The change of the set point which I used a rotary encoder for is possible. The setting figure by the
rotary encoder agrees with a position of movement figure indication displayed in early period of
main body by a screen.
The increment can be changed by pressing “RE” after pressing “ENT”.
The CC_No can be set from 1 to 16.
The CC_No is skipped when effective time (2) is set as 0.
・ During the dynamic mode operation, if you change parameters, the setting becomes effective
immediately.
SET(CC1)
SET(CC2)
TIME (msec)
Current (A)
TIME(CC1) TIME(CC2)
RESP(CC1)
(A/μsec)
RESP(CC2)
(A/μsec)