2600AS-901-01 Rev. B / September 2008 Return to Section Topics C-11
Series 2600A System SourceMeter® Instruments Reference Manual Appendix C: Status Model
Status function summary
The following functions and attributes control and read the various registers (Table C-1). Additional
information is included later in the section in command listings for the various register sets.
Table C-1
Status function summary
Type Function or attribute
1
System summary status.condition
status.node_enable
status.node_event
status.request_enable
status.request_event
status.reset
Measurement event status.measurement.*
status.measurement.buffer_available.*
status.measurement.current_limit.*
status.measurement.instrument.*
status.measurement.instrument.smuX.*
status.measurement.reading_overflow.*
status.measurement.voltage_limit.*
Operation event status.operation.*
status.operation.calibrating.*
status.operation.instrument.*
status.operation.instrument.digio.*
status.operation.instrument.digio.trigger_overrun.*
status.operation.instrument.lan.*
status.operation.instrument.lan.trigger_overrun.*
status.operation.instrument.smuX.*
status.operation.instrument.smuX.trigger_overrun.*
status.operation.instrument.trigger_blender.*
status.operation.instru-
ment.trigger_blender.trigger_overrun.*
status.operation.instrument.trigger_timer.*
status.operation.instru-
ment.trigger_timer.trigger_overrun.*
status.operation.instrument.tsplink.*
status.operation.instrument.tsplink.trigger_overrun.*
status.operation.measuring.*
status.operation.remote.*
status.operation.sweeping.*
status.operation.trigger_overrun.*
status.operation.user.*
Questionable event status.questionable.*
status.questionable.calibration.*
status.questionable.instrument.*
status.questionable.instrument.smuX.*
status.questionable.over_temperature.*
status.questionable.unstable_output.*
status.questionable.over_temperature.*
status.questionable.unstable_output.*
Standard event status.standard.*
System events status.system.*
status.system2.*
status.system3.*
status.system4.*
status.system5.*
1. * = ‘.condition’, ‘.event’, '.ntr', '.ptr' and '.enable'; smuX = smua or smub.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keithley 2600a series and is the answer not in the manual?

Keithley 2600a series Specifications

General IconGeneral
BrandKeithley
Model2600a series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals