  • J
    Jeffery BellSep 13, 2025
    Why doesn't the Num Lock LED light up on my Keysight E4990A keyboard?
    • S
      Sue Carroll DDSSep 13, 2025
      If the LED on the keyboard of your Keysight Measuring Instruments unit doesn't light up when you press the Num Lock key, there might be an issue with the A60 CPU module. Before replacing the A60 CPU module, verify that all connections to it are secure and normal, without any disconnections or loose connections.
  • R
    rodriguezchristopherSep 12, 2025
    What to do if multiple keys don't work on the Keysight Measuring Instruments front panel?
    • V
      Victor HansenSep 12, 2025
      If multiple keys on the front panel of your Keysight Measuring Instruments unit are not working, the problem might be with the A52 Front Panel I/F board or the A60 CPU Module. Also, check the flat cable between the A52 Front Panel I/F board and A60 CPU Module.
  • F
    Frances BeasleySep 12, 2025
    Why does the display on my Keysight E4990A Measuring Instruments white out or turn blue during startup?
    • D
      Dennis PriceSep 12, 2025
      If your Keysight Measuring Instruments unit's display whites out, turns entirely blue, or shows a dialog box during system initialization, a mass storage problem is suspected. Try performing the mass storage recovery procedure.
  • M
    Melissa PonceSep 10, 2025
    What to do if the system fan inside Keysight E4990A Measuring Instruments doesn't run?
    • L
      Lori HillSep 10, 2025
      If the system fan inside your Keysight Measuring Instruments unit isn't running, the issue might be with the A51 DSP board or the flat cable connecting it to the A60 CPU module. Remove the outer cover of the E4990A to see if the fan starts running.
  • V
    Veronica LopezSep 9, 2025
    Why isn't the rear panel fan running on my Keysight Measuring Instruments?
    • V
      Valerie MorrisonSep 9, 2025
      If the rear panel fan (blower) of your Keysight Measuring Instruments unit isn't running, it's likely due to a power supply failure. Remove the outer cover of the E4990A and check if the +3.3 V and +5 V DC monitor LEDs on the A60 CPU module are lit.
  • A
    Aaron YoungSep 8, 2025
    What to do if Keysight E4990A beeps and shuts down immediately after power on?
    • B
      Beverly HoldenSep 8, 2025
      If your Keysight Measuring Instruments unit beeps and shuts down immediately after powering on, the shutdown occurs because the system fan has stopped working. You should check the fan.
  • D
    David HawkinsAug 23, 2025
    How to troubleshoot external controller issues with Keysight E4990A?
    • A
      Amy NormanAug 23, 2025
      If your Keysight Measuring Instruments system doesn't respond to an external controller or fails to function normally, ensure the GPIB address is defined correctly, the GPIB cable is connected, no other instrument connected by the GPIB cable has the same GPIB address, and the GPIB cable connection does not form a loop.
  • J
    jennifersmithSep 6, 2025
    Why date and time are incorrect on Keysight Measuring Instruments after startup?
    • J
      Joseph HowardSep 6, 2025
      If the measurement screen appears after startup, but the date and time displayed on the instrument status bar in the lower right part of the screen differ greatly from the previous settings on your Keysight Measuring Instruments, execute the system recovery.
  • C
    Christine ShortSep 5, 2025
    Why Keysight E4990A enters service mode after startup?
    • W
      Wesley RodriguezSep 5, 2025
      If the Keysight Measuring Instruments system starts up but enters the service mode, execute the system recovery.
  • M
    Marcus StokesSep 4, 2025
    What to do if Keysight E4990A shuts down immediately after startup?
    • D
      dhendersonSep 4, 2025
      If the Keysight Measuring Instruments system starts up but automatically shuts down immediately, execute the system recovery.

Summary

Using this Help

Opening E4990 A Help

Describes how to open the E4990A Help system.

Context Sensitive Help

Explains how to get context-sensitive help by pressing the Help key or F1.

Viewing E4990 A Help on your PC

Guides on opening and viewing the E4990A Help file on a PC.

Navigating E4990 A Help

Describes navigation methods within the help system.

Conventions used in E4990 A Help

Details naming conventions used in the help system, like file names and paths.

Precautions

Safety

Outlines general safety precautions for operation, service, and repair of the instrument.

Installing Software

Instructions for updating pre-installed software and installing user application software.

Protecting the E4990 A

Instructions to protect the E4990A, including reading warning labels and handling power cables.

Precaution for input connector and cable

Precautions regarding excessive voltage/current to test ports and bending cables.

Precautions for Electrostatic Discharge (ESD)

Guidelines for preventing ESD damage to electronic components.

Before Contacting us

Troubleshooting steps for startup or operation problems before contacting support.

Quick Start

Front Panel: Names and Functions of Parts

Details the names and functions of the parts on the E4990A front panel.

Rear Panel: Names and Functions of Parts

Details the names and functions of the parts on the E4990A rear panel.

Hardkeys

Describes hardkeys for selecting channels and traces.

LCD Screen

Information about the touch-sensitive LCD screen for displaying traces and settings.

USB Ports

Information on USB ports for connecting peripherals like keyboards and printers.

Measurement

Preparation of Measurement Accessories

Steps for selecting, connecting, and setting up measurement accessories.

Setting Measurement Conditions

Explains how to set up measurement conditions including signal and sweep.

Calibration

Describes various calibration methods for the E4990A Impedance Analyzer.

Setting Up the Display of Measurement Results

How to configure the E4990A to display measurement results effectively.

Analysis and Processing of Result

Guides through analyzing data using markers and performing calculations.

Setting Control Functions

Setting the GPIB

Details on setting talker/listener GPIB addresses for E4990A control.

Remote Control Using HTTP (Web Browser)

Enables control of the E4990A via a web browser using HTTP.

Using Windows

Provides guidance on using Windows features and settings on the E4990A.

Configuring Network

Steps to configure network settings for LAN connectivity.

Windows Firewall

Instructions on how to turn Windows Firewall ON or OFF.

User Account and Password

Information on managing user accounts and passwords for system access.

Product Information

Options for E4990 A

Lists available options for the E4990A, including frequency and time base options.

Documentations for E4990 A

Lists available documentation such as manuals, sales literature, and specifications.

Troubleshooting

Guides on identifying and resolving common operational issues and errors.

Maintenance

Covers procedures for cleaning, part replacement, and system recovery.

Programming

Remote Control

Information on controlling the E4990A remotely via GPIB, LAN, or USB.

Types of Remote Control System

Details the five types of remote control systems based on system controller and interface.

LAN remote control system

Overview of controlling the E4990A using SICL-LAN or telnet server.

USB Remote Control System

Overview of device control via USB, equivalent to GPIB control.

Sending SCPI Command Messages

Information on SCPI commands, their types, structure, and grammar.

Command Reference

Comprehensive reference for all SCPI commands and their syntax.

Index

Keysight E4990A Specifications

General IconGeneral
BrandKeysight
ModelE4990A
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals