[SOURce:]
FUNCtion
CURRent|VOLTage, (@<chanlist>) Sets the output regulation - voltage priority or current priority.
[SOURce:]
VOLTage
[:LEVel]
[:IMMediate]
[:AMPLitude] <value>, (@<chanlist>) Sets the output voltage when in voltage priority mode.
:LIMit
[:POSitive]
[:IMMediate]
[:AMPLitude] <value>, (@<chanlist>) Sets the positive voltage limit when in current priority mode.
:LOW <value>, (@<chanlist>) Sets the low voltage limit when in current priority mode.
:DTABle
[:IMMediate]? (@<chanlist>) Returns the table currently being used by the channel.
:SASimulator
[:IMMediate]? (@<chanlist>) Returns the DAC table based on the SAS parameter settings.
:VMP? (@<chanlist>) Returns the calculated Vmp of the internal DAC table.
:VOC? (@<chanlist>) Returns the calculated Voc of the internal DAC table.
:TABLe
[:IMMediate]? <"name">, (@<chanlist>) Returns the DAC table based on the SAS parameter table settings.
:VMP? <"name">, (@<chanlist>) Returns the calculated Vmp of the internal DAC table.
:VOC? <"name">, (@<chanlist>) Returns the calculated Voc of the internal DAC table.
:PROTection
[:LEVel] <value>, (@<chanlist>) Sets the over-voltage protection level
:DELay <value>, (@<chanlist>) Sets the over-voltage protection delay
:SASimulator
:SCALe <percent>, (@<chanlist>) Specifies the voltage scale in SAS mode.
:VMP <value> Sets the voltage at the Vmp point of the curve in SAS mode.
:VOC <value> Sets the Voc voltage of the curve in SAS mode.
Keysight MP4300 Series Operating and Service Guide 25