Common Characteristic Keysight MP4301A & MP4302A
Environmental
Operating environment:
Temperature range:
Relative humidity:
Altitude:
Storage temperature:
LED statement:
Indoor use, installation category III, pollution degree 2
0°C to 55°C (Maximum current is derated at 1% per degree C from 40°C to 55°C)
Up to 95% RH
Up to 2000 meters
-30°C to 70°C
Any LEDs used in this product are Class 1 LEDs as per IEC 825-1
Regulatory Compliance
EMC:
Safety:
Complies with European EMC Directive for test and measurement products
Complies with Australian standard and carries C-Tick mark
This ISM device complies with Canadian ICES-001
Cet appareil ISM est conforme à la norme NMB-001 du Canada
Complies with European Low Voltage Directive and carries the CE mark.
Conforms to US and Canadian safety regulations.
Declarations of Conformity for this product may be downloaded from the Web. Go to
http://www.keysight.com/go/conformity and click on “Declarations of Conformity.”
AC Input
Connections:
Phase and range:
Frequency:
Input VA:
Input current per phase:
Efficiency at full power:
Power Factor:
L1, L2, L3, and PE (does not require a neutral connection)
MP4301A - 3 phase; 200 VAC ± 10% and 208 VAC ± 10%
MP4302A - 3 phase; 380 VAC ± 10%, 400VAC ± 10% and 480 VAC ± 10%
47 - 63 Hz (400 Hz not supported)
7.2 kW
MP4301A - 23.1 A for 200 V models,
MP4302A - 12.2A for 400 V models
85%
0.99 @ nominal input and rated power
Output Terminal Isolation No output terminal may be more than ±240 VDC from any other terminal or chassis ground.
Typical Weight MPS mainframe: 42.4 lbs (19.3 kg)
Power module: 3.8 lbs (1.7 kg)
Fully loaded mainframe: 65.2 lbs (29.5 kg)
Dimensions See Outline Diagram for details
1 Quick Reference
32 Keysight MP4300 Series Operating and Service Guide