3 Short-Range Comms & IoT Mode
3.7 ACP Measurement
Backwards
Compatibility
SCPI
[:SENSe]:ACPower:OFFSet[1]|2:LIST:BWIDth:RESolution:AUTO
Video BW
Enables you to change the instrument post-detection filter (VBW).
Remote Command
[:SENSe]:ACPower:OFFSet[1]|2[:OUTer]:LIST:BANDwidth:VIDeo <freq>,…
[:SENSe]:ACPower:OFFSet[1]|2[:OUTer]:LIST:BANDwidth:VIDeo?
Subopcode: 1 = BTS/Downlink (Default), 2 = MS/Uplink
Example
:ACP:OFFS2:LIST:BAND:VID 5MHz,5MHz,5MHz,5MHz,5MHz,5MHz
:ACP:OFFS2:LIST:BAND:VID?
Notes The values shown in this table reflect the conditions after Mode Preset
Some Modes do not support Offset subopcode 2. In those cases, commands with subopcode 2 are
accepted without error but ignored
Dependencies When "Meas Method" on page 863 is RBW, FAST or Fast Power, this cell is grayed-out and disabled. If
the cell is pressed, an advisory message is generated. If the equivalent remote command is sent, a
"Setting conflict" warning is generated
Preset When "Max Num of Offsets" on page 902 is 12, the preset value of Offset G ~ L is the same as the
Offset F value
Modes Values
SA 22 kHz, 22 kHz, 22 kHz, 22 kHz, 22 kHz, 22 kHz
WCDMA 1 MHz, 1 MHz, 1 MHz, 1 MHz, 1 MHz, 1 MHz
LTEAFDD, LTEATDD, 5G NR, MSR 1 MHz, 1 MHz, 1 MHz, 1 MHz, 1 MHz, 1 MHz
State Saved Saved in instrument state
Min/Max 1 Hz/50 MHz
Backwards
Compatibility SCPI
[:SENSe]:ACPower:OFFSet[1]|2:LIST:BWIDth:VIDeo
Auto Function
Remote
Command
[:SENSe]:ACPower:OFFSet[1]|2[:OUTer]:LIST:BANDwidth:VIDeo:AUTO OFF | ON | 0
| 1,…
[:SENSe]:ACPower:OFFSet[1]|2[:OUTer]:LIST:BANDwidth:VIDeo:AUTO?
Subopcode: 1 = BTS/Downlink (Default), 2 = MS/Uplink
Example
:ACP:OFFS2:LIST:BAND:VID:AUTO 0,0,0,0,1,1
:ACP:OFFS2:LIST:BAND:VID:AUTO?
Preset When "Max Num of Offsets" on page 902 is 12, the preset value of Offset G ~ L is ON
ON, ON, ON, ON, ON, ON
880 Short Range Comms & IoT Mode User's &Programmer's Reference

Table of Contents

Other manuals for Keysight N9010B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight N9010B and is the answer not in the manual?

Keysight N9010B Specifications

General IconGeneral
BrandKeysight
ModelN9010B
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals