Example 4-1: Set the denominator of electronic gear ratio to 10000 with
number system switching
Press MODE. The main menu is displayed. Choose F003.
Press ENTER. The interface for selecting addresses is displayed.
Press ▲ to adjust data as d3.35.
Press ENTER to display the current value d3.35. Press ENTER again to modify the value d3.35. In this
case, the 1
st
number at the right side is flickering. Short press MODE for three times to move to the first
position on the left. Then press ▲. The value is increased to 9000. In this case, the current data is
decimal.
Press ▲ again. The content of numeric display changes to “271.0”, and the 3
rd
decimal point (from left to
right) flickers. In this case, the data is hexadecimal. Press ENTER to confirm the current value. The 1
st
decimal point on the right flickers. In this case, the denominator of the electronic gear ratio is modified to
10000.
Figure 4-2 Number system conversion
Example 4-2: Set the speed to 1000 RPM/-1000 RPM with separate
regulation of bits
Press MODE. The main menu is displayed. Choose F000.
Press ENTER. The interface for selecting addresses is displayed.
Press ▲ to adjust data as d0.02.
Press ENTER to display the current value d0.02. Press ENTER again to modify the value d0.02. In this
case, the 1
st
number at the right side is flickering.
Short press MODE for three times to move to the 1
st
position on the left. Press ▲ to modify the value to 1.
Press ENTER to confirm the current value. The 1
st
decimal point on the right flickers. In this case, the
speed is 1000 RPM.
Press ▼ to modify the value to -1. In this case, the 1
st
decimal point on the left flickers, indicating that the
current data is negative. Press ENTER to confirm the current value. The 1
st
decimal point on the right
flickers. In this case, the speed is -10000 RPM.