Kinco JD Series Servo User Manual
Parameter List: Group F005 (To Set Driver Parameters)
1: Stores all control parameters
except motor parameters
10: Initializes all control parameters
except motor parameters
Station No. of Drivers
Note: To change this parameter, you
need to save it with the address
“d5.00”, and restart it later.
Set the baud rate of RS232 port
540 19200
270 38400
90 115200
Note: To change this parameter, you
need to save it with the address
“d5.00”, and restarts it later.
Sets the baud rate of RS232 port
540 19200
270 38400
90 115200
You need not restart it,but it can’t be
saved.
Indicates the values of braking
resistors
Indicates the nominal power of a
braking resistor
Indicates the time constant of a
braking resistor
Time: N*256/1000 Unit: S
Indicates data configuration of U
phase shift.
Note:Factory parameters
Indicates data configuration of V
phase shift
Note:Factory parameters
ADC original data when DC bus
voltage is 200 V
Note:Factory parameters
ADC original data when DC bus
voltage is 360 V
Note:Factory parameters
Indicates the excitation pointer of a
motor
Note:Factory parameters
Indicates error masks
Note:Factory parameters
Indicates the relay operating time of
capacitor short-circuits
Unit: mS
Note:Factory parameters
Sets numeric display data