DIAGNOSTICS Error Codes
10DEC05
DG4825-1
Page
110 of 180
Communications for the MOTION SYSTEM CONTROL BOARD
32001 - Communications malfunctioned between MCPU and SSC BOARDS
32002 - MSC BOARD A1: Internal Communications Error
32003 - MSC BOARD A1: Internal Communications Error
32004 - Communications Error between MCPU and SSC BOARDS
Description: A message from the MASTER CENTRAL PROCESSING UNIT BOARD
A2 did not complete before another message was received.
Cause 1: The MASTER CENTRAL PROCESSING UNIT BOARD A2 malfunctioned.
Action: Do the checkout for the MASTER CENTRAL PROCESSING UNIT BOARD A2.
Cause 2: The MOTION SYSTEM CONTROL BOARD A1 malfunctioned.
Action: Do the checkout for the MOTION SYSTEM CONTROL BOARD A1.
Cause 3: The SLOW SCAN CONTROLLER BOARD A6 malfunctioned.
Action: Do the checkout for the SLOW SCAN CONTROLLER BOARD A6 and COIL
BOARD A7.
Description: A malfunction occurred with the RS-232 communications on the MOTION
SYSTEM CONTROL BOARD A1.
Cause: The MOTION SYSTEM CONTROL BOARD A1 malfunctioned.
Action: Do the checkout for the MOTION SYSTEM CONTROL BOARD A1.
Description: A malfunction occurred with the RS-232 communications on the MOTION
SYSTEM CONTROL BOARD A1.
Cause: The MOTION SYSTEM CONTROL BOARD A1 malfunctioned.
Action: Do the checkout for the MOTION SYSTEM CONTROL BOARD A1.
Description: A message was sent to the SLOW SCAN CONTROLLER BOARD A6
and a response was not received within 3 seconds.