DIAGNOSTICS Error Codes
10DEC05
DG4825-1
Page
68 of 180
11017 - MSC BOARD A1: Software Error for DUPLEX CAM
11018 - DUPLEX CAM did not move to next position
11019 - DUPLEX CAM did not move to “PINCH” position
11020 - DUPLEX CAM did not move to “UNLATCH” position
Cause: The MOTION SYSTEM CONTROL BOARD A1 malfunctioned.
Action: Do the checkout for the MOTION SYSTEM CONTROL BOARD A1.
Description: The MOTION SYSTEM CONTROL BOARD A1 did not set up the
command to move for the DUPLEX CAM.
Cause: The MOTION SYSTEM CONTROL BOARD A1 malfunctioned.
Action: Do the checkout for the MOTION SYSTEM CONTROL BOARD A1.
Cause: The DUPLEX CAM malfunctioned.
Action: Do the checkout for the CASSETTE HANDLING AY.
Cause 1: The DUPLEX CAM malfunctioned.
Action: Do the checkout for the CASSETTE HANDLING AY.
Cause 2: The SLOW SCAN CONTROLLER BOARD A6 malfunctioned.
Action: Do the checkout for the SLOW SCAN CONTROLLER BOARD A6 and COIL
BOARD A7.
Cause 1: The MOTION SYSTEM CONTROL BOARD A1 malfunctioned.
Action: Do the checkout for the MOTION SYSTEM CONTROL BOARD A1.
Cause 2: The DUPLEX CAM malfunctioned.
Action: Do the checkout for the CASSETTE HANDLING AY.