COMMON RAIL SYSTEM
07-CR-E5,07-CR-TE5,07-CR-TIE5, DM
1-S78
9Y3200007CRS0116US0
Name Fuel high temperature
ISO 14229
P-Code
P0181
J1939-73
SPN 174
FMI 0
SPN Name
SAE J1939 Table C1
Fuel Temperature
DTC Name Fuel high temperature
Detection item Fuel temperature high
DTC Set
Preconditions
Passed 300 sec. after cranking
Engine speed is 800 min
-1
(rpm) or more
Fuel temperature sensor is normal
DTC set parameter Fuel temperature higher than 90 °C (194 °F)
Time to action or
number of error
detection
10 sec. or more
Limp Home Action
by engine ECU
(system action)
Output limitation: Approximately 75 % of normal condition
Behaviour During
Malfunction
•None
Engine Warning
Light
•ON
Recovery from
error
Diagnostic counter = zero or Key switch turn OFF
Delay time for
recovery
30 sec.
Remark
KiSC issued 03, 2022 A