COMMON RAIL SYSTEM
07-CR-E5,07-CR-TE5,07-CR-TIE5, DM
1-S79
9Y3200007CRS0117US0
Name Fuel temperature sensor abnormality
ISO 14229
P-Code
P0182 P0183
J1939-73
SPN 174 174
FMI 43
SPN Name
SAE J1939 Table C1
Engine Fuel Temperature 1 Engine Fuel Temperature 1
DTC Name Fuel temperature sensor: Low Fuel temperature sensor: High
Detection item
• Ground short circuit of sensor / harness • Open circuit or +B short circuit of sensor
/ harness
DTC Set
Preconditions
• Battery voltage is normal • Battery voltage is normal
DTC set parameter
• Voltage of temperature sensor in supply
pump is 0.1 V or less
• Voltage of temperature sensor in supply
pump is 4.9 V or above
Time to action or
number of error
detection
• 2.8 sec. or more • 2.8 sec. or more
Limp Home Action
by engine ECU
(system action)
• During start-up = −20 °C (−4 °F)
[default value]
• Under other conditions = 45 °C (113 °F)
[default value]
• Output limitation: Approximately 75 % of
normal condition
• During start-up = −20 °C (−4 °F)
[default value]
• Under other conditions = 45 °C (113 °F)
[default value]
• Output limitation: Approximately 75 % of
normal condition
Behaviour During
Malfunction
• None • None
Engine Warning
Light
•ON •ON
Recovery from
error
• Diagnostic counter = zero
or Key switch turn OFF
• Diagnostic counter = zero
or Key switch turn OFF
Delay time for
recovery
• 30 sec. • 30 sec.