EasyManua.ls Logo

Kubota 07-CR-E5 - Page 132

Kubota 07-CR-E5
373 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
COMMON RAIL SYSTEM
07-CR-E5,07-CR-TE5,07-CR-TIE5, DM
1-S94
9Y3200007CRS0132US0
Name QR data abnormality
ISO 14229
P-Code
P0602 P0602
J1939-73
SPN 523538 523538
FMI 27
SPN Name
SAE J1939 Table C1
proprietary proprietary
DTC Name QR data error No QR data
Detection item QR data read error QR data is unwritten
DTC Set
Preconditions
Key switch is ON Key switch is ON
DTC set parameter QR data read error from EEPROM Area of QR data on EEPROM is vacant
Time to action or
number of error
detection
Transient Transient
Limp Home Action
by engine ECU
(system action)
Nozzle caribration is not executed
Output limitation: Approximately 75 % of
normal condition
Nozzle correction factor = 0
[default value]
Output limitation: Approximately 75 % of
normal condition
Behaviour During
Malfunction
Insufficient output Insufficient output
Engine Warning
Light
•ON •ON
Recovery from
error
Key switch turn OFF Key switch turn OFF
Delay time for
recovery
––
Remark To cover each injector dispersion
KiSC issued 03, 2022 A

Table of Contents