COMMON RAIL SYSTEM
07-CR-E5,07-CR-TE5,07-CR-TIE5, DM
1-S94
9Y3200007CRS0132US0
Name QR data abnormality
ISO 14229
P-Code
P0602 P0602
J1939-73
SPN 523538 523538
FMI 27
SPN Name
SAE J1939 Table C1
proprietary proprietary
DTC Name QR data error No QR data
Detection item • QR data read error • QR data is unwritten
DTC Set
Preconditions
• Key switch is ON • Key switch is ON
DTC set parameter • QR data read error from EEPROM • Area of QR data on EEPROM is vacant
Time to action or
number of error
detection
• Transient • Transient
Limp Home Action
by engine ECU
(system action)
• Nozzle caribration is not executed
• Output limitation: Approximately 75 % of
normal condition
• Nozzle correction factor = 0
[default value]
• Output limitation: Approximately 75 % of
normal condition
Behaviour During
Malfunction
• Insufficient output • Insufficient output
Engine Warning
Light
•ON •ON
Recovery from
error
• Key switch turn OFF • Key switch turn OFF
Delay time for
recovery
––
Remark • To cover each injector dispersion
KiSC issued 03, 2022 A

Table of Contents