EasyManua.ls Logo

Kubota 07-CR-E5 - Page 145

Kubota 07-CR-E5
373 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
COMMON RAIL SYSTEM
07-CR-E5,07-CR-TE5,07-CR-TIE5, DM
1-S107
9Y3200007CRS0143US0
Name Accelerator position sensor 2 abnormality
ISO 14229
P-Code
P2127 P2128
J1939-73
SPN 29 29
FMI 43
SPN Name
SAE J1939 Table C1
Accelerator Pedal Position 2 Accelerator Pedal Position 2
DTC Name Accelerator position sensor 2: Low Accelerator position sensor 2: High
Detection item
Ground short circuit or open circuit of
sensor / harness
Battery short circuit out of sensor /
harness
DTC Set
Preconditions
Battery voltage is normal
Sensor supply voltage VCC1 is normal
Battery voltage is normal
Sensor supply voltage VCC1 is normal
DTC set parameter
Voltage of accelerator position sensor 2
is 0.3 V or less
Voltage of accelerator position sensor 2
is 4.8 V or more
Time to action or
number of error
detection
•Transient •Transient
Limp Home Action
by engine ECU
(system action)
Forced Idle (Accelerator = 0 %) Forced Idle (Accelerator = 0 %)
Behaviour During
Malfunction
Insufficient output Insufficient output
Engine Warning
Light
•ON •ON
Recovery from
error
Diagnostic counter = zero
or Key switch turn OFF
Diagnostic counter = zero
or Key switch turn OFF
Delay time for
recovery
3 sec. 3 sec.
Remark
KiSC issued 03, 2022 A

Table of Contents

Related product manuals