COMMON RAIL SYSTEM
07-CR-E5,07-CR-TE5,07-CR-TIE5, DM
1-S127
9Y3200007CRS0162US0
Name
High exhaust gas temperature after
emergency high temperature DTC
High frequency of regeneration
ISO 14229
P-Code
P3023 P3024
J1939-73
SPN 523601 523602
FMI 00
SPN Name
SAE J1939 Table C1
proprietary proprietary
DTC Name
High exhaust gas temperature after
emergency high temperature DTC
High frequency of regeneration
Detection item
Exhaust gas temperature sensor (T
0
, T
1
and T
2
) output
Time interval from the end time to the
start time of the regeneration
DTC Set
Preconditions
Battery voltage is normal Battery voltage is normal
Key switch is ON
DTC set parameter
All exhaust gas temperature (T
0
, T
1
and
T
2
) reduces down to 300 °C (572 °F)
Regeneration time interval within 30 min.
occurs three times continuously
Time to action or
number of error
detection
•Transient •Transient
Limp Home Action
by engine ECU
(system action)
Engine stop
Inhibit starter relay activation until all
exhaust gas temperature (T
0
, T
1
and T
2
)
reduces down to 300 °C (572 °F)
Output limitation: Approximately 50 % of
normal condition
•EGR stop
Behaviour During
Malfunction
None Worsening exhaust gas performance
(NOx)
Engine Warning
Light
•ON •ON
Recovery from
error
Diagnostic counter = zero
or Key switch turn OFF
Key switch turn OFF
(Reset by Service tool)
Delay time for
recovery
Immediately
Remark
KiSC issued 03, 2022 A

Table of Contents