EasyManuals Logo

Labrie automizer Service Manual

Labrie automizer
243 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #218 background imageLoading...
Page #218 background image
208 Multiplexing
Cummins Engine Parameters
The following table contains the engine programming parameters specific to the AUTOMIZER™ units.
Enter those parameters into Cummins engine ECMs. For more information, call LabriePlus.
Table 9 Cummins engine parameters
Menu: Features &
Parameters
Parameter Name Value
Adjustable low idle
speed
Low idle speed adjustment switch
---------------------------------------------------------------
Low idle speed
Disable
--------------------
700 rpm
Switched maximum
engine operating speed
Switched maximum engine operating speed
---------------------------------------------------------------
Maximum operating speed switch setup
---------------------------------------------------------------
Maximum switched engine speed
Enable
--------------------
Active closed
--------------------
900 rpm

Table of Contents

Other manuals for Labrie automizer

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Labrie automizer and is the answer not in the manual?

Labrie automizer Specifications

General IconGeneral
BrandLabrie
Modelautomizer
CategoryAutomobile
LanguageEnglish

Related product manuals