208 Multiplexing
Cummins Engine Parameters
The following table contains the engine programming parameters specific to the AUTOMIZER™ units.
Enter those parameters into Cummins engine ECMs. For more information, call LabriePlus.
Table 9 Cummins engine parameters
Menu: Features &
Parameters
Parameter Name Value
Adjustable low idle
speed
Low idle speed adjustment switch
---------------------------------------------------------------
Low idle speed
Disable
--------------------
700 rpm
Switched maximum
engine operating speed
Switched maximum engine operating speed
---------------------------------------------------------------
Maximum operating speed switch setup
---------------------------------------------------------------
Maximum switched engine speed
Enable
--------------------
Active closed
--------------------
900 rpm