Troubleshooting 9-5
D-I012.1109EN
innovators in agriculture
25 SHORT-CIR. 1L Short-circuit motor 1 Left
wheel
1. Call your local Lely service provider.
26 SHORT-CIR. 2R Short-circuit motor 2 Right
wheel
1. Call your local Lely service provider.
27 BACKUP ERROR Error backup: Try again!
1. Make sure the E-Link is connected
properly.
2. Make sure to use the correct E-Link
software version (page VII).
3. Try to make another backup (page
6-13).
4. If the problem remains, call your local
Lely service provider.
29 NO_GYRO_STAR
T
Factory startup gyro failed!
Cooldown gyro and startup
gyro again
1. Call your local Lely service provider.
30 M1 THERMISCH Motor 1 thermic out
1. Call your local Lely service provider.
31 M2 THERMISCH Motor 2 thermic out
1. Call your local Lely service provider.
32 COOL DOWN Gyro is too hot to do a factory
startup. Let gyro cool down
first
For information only.
33 FULL CHARGING
Battery is recharging. For information
only.
34 BATT FULL
Battery is full. For information only.
35 BATT ERROR
Battery recharge failed/mains voltage is
too low.
1. Call your local Lely service provider.
36 NO_GYRO_STAR
T
Gyroscope does not startup
correct!
1. Call your local Lely service provider.
37 GYRO
ANGLEFACT
Angle calibration gyro not
correct
1. Call your local Lely service provider.
38 LOADING No charging current! Check
charge strips for dirt
1. Clean the charging strips and the
charging electrodes (page 7-4).
Make sure the battery is charging (page
8-3).
39 GYRO_TEMP Gyroscope not on
temperature! Check power
supply
1. Call your local Lely service provider.
40 CAL_IND_ZERO Inductive sensor values not
correct --> much deviation!!
Are the sensors above guide
strip?
1. Make sure the inductive sensors are
installed 1-2 cm above the floor.
2. Adjust the height of the inductive
sensors if necessary (page 5-15).
3. Make sure the inductive sensors are
installed level.
4. Level the inductive sensors if
necessary (page 5-15).
5. If the problem remains, call your local
Lely service provider.