Description and Operation 4-19
D-I012.1109EN
innovators in agriculture
Buttons:
• [
] or [ ] to modify the value of the selected variable
• [START/STOP] to start or stop
• Soft button [MAN] to adjust the position of the vehicle.
Ultrasound L
Tracking along a wall or fence on the left at a certain distance. The
ultrasonic sensor is used to measure the distance to the wall or fence.
The display shows the following information:
Display Description
• Actionr: sequence number for the action
in this route
• RunDst: distance travelled in mm
• UltraDst: actual distance to the wall or
fence (mm)
• ULTRADST: adjustable distance to the
wall or fence (mm).
Buttons:
• [
] or [ ] to modify the value of the selected variable
• [START/STOP] to start or stop
• Soft button [MAN] to adjust the position of the vehicle.
Charger strip
Drive the vehicle back to the charging station. The JUNO 150 follows the
metal strip on the floor and finds the charging station independently
(default = on the left) (page 4-1). The vehicles nose must be placed
within 1 m (39.4 in) before the strip into the direction of the charging
station.
The display shows the following information:
Display Description
• Actionr: sequence number for the action
in this route
• RunDst: distance travelled in mm
• Strip: indicates 1 when above the strip.
Buttons:
• Soft button [L] to modify the position of the charging station
• Soft button [MAN] to adjust the position of the vehicle
• [START/STOP] to start or stop.