•Tomaintainpropersystemcooling,donotoperatetheserverformorethan10minuteswithouteithera
driveorafillerpanelinstalledineachdrivebay.
Readthesafetyinformationin“Safety”onpagevand“Installationguidelines”onpage29.
Ifyouarereplacingaservercomponentintheserver,youneedtoturnofftheserverandperipheraldevices,
anddisconnectthepowercordsandallexternalcables.
Toinstalla3.5-inchsimple-swapharddiskdrive,completethefollowingsteps.
Step1.Turnofftheserverandperipheraldevicesanddisconnectallpowercords.
Step2.Unlocktheleft-sidecover.
Note:Youmustunlocktheleft-sidecovertoopenorremovethebezel.Whenyoulocktheleft-side
cover,itlocksboththecoverandthebezel.
Step3.Openthebezel(see“Removingthebezel”onpage184).
Step4.Removethefillerpanel,ifoneispresent.
Step5.Touchthestatic-protectivepackagethatcontainsthediskdrivetoanyunpaintedmetalsurfaceon
theserver;then,removethediskdrivefromthepackageandplaceitonastatic-protectivesurface.
Step6.Grasptheblackdrivehandleandslidethebluereleaselatchtotherightandalignthedrive
assemblywiththeguiderailsinthebay.
Handle
Latch
3.5-inch simple-swap
hard disk drive
3.5-inch filler panel
Figure125.Simple-swapharddiskdriveinstallation
Step7.Gentlypushthedriveintothebayuntilthedrivestops.
Step8.Closethebezel(see“Installingthebezel”onpage186).
Step9.Locktheleft-sidecover.
206Systemx3500M5InstallationandServiceGuide