Fan
Fan-locking handle
Figure146.Openthefan-lockinghandle
Step4.Ifyouareinstructedtoreturnthehot-swapfan,followallpackaginginstructions,anduseany
packagingmaterialsforshippingthataresuppliedtoyou.
Installingahot-swapfan
Usethisinformationtoinstallahot-swapfanintheserver.
Attention:Toavoidunexpectedsystemshutdown,ensurethatyoulaytheserveronitssidewiththe
coverfacingupbeforeyoustart.
Attention:Staticelectricitythatisreleasedtointernalservercomponentswhentheserverispowered-on
mightcausetheservertohalt,whichmightresultinthelossofdata.Toavoidthispotentialproblem,
alwaysuseanelectrostatic-dischargewriststraporothergroundingsystemwhenyouworkinsidethe
serverwiththepoweron.
Readthesafetyinformationin“Safety”onpagev
and“Installationguidelines”onpage29.
Ifyouarereplacingaservercomponentintheserver,youneedtoturnofftheserverandperipheraldevices,
anddisconnectthepowercordsandallexternalcables.
Toinstallahot-swapfan,completethefollowingsteps.
Step1.Carefullyturntheserveronitssidesothatitislyingflat,withthecoverfacingup.
Step2.Touchthestatic-protectivepackagethatcontainsthehot-swapfantoanyunpaintedmetalsurface
ontheserver;then,removethefanfromthepackage.
Step3.Unlockandremovetheleft-sidecover(see“Removingtheleft-sidecover”onpage182).
Step4.Openthefan-lockinghandleofthereplacementfan.
Step5.Insertthefanintothesocketandclosethehandletothelockedposition.
226Systemx3500M5InstallationandServiceGuide