8400 BaseLine D | Software Manual
Parameter reference
Table of attributes
220 L Firmware 03.00 - DMS EN 5.0 - 07/2009
C00027 AINx: Gain 24548 5FE4 A 1 INTEGER_32 100 ;;
C00028
AINx: Input voltage 24547 5FE3 A 1 INTEGER_16 100 ;
C00029
AINx: Input current 24546 5FE2 A 1 INTEGER_16 100 ;
C00033
AINx: Output value 24542 5FDE A 1 INTEGER_16 100 ;
C00034
AINx: Configuration 24541 5FDD A 1 UNSIGNED_8 1 ;;
C00036
DCB: Current 24539 5FDB E 1 INTEGER_16 100 ;;
C00039
Fixed setpoint x (L_NSet_1 n-Fix) 24536 5FD8 A 3 INTEGER_16 100 ;;
C00050
MCTRL: Speed setpoint 24525 5FCD E 1 INTEGER_32 1 ;
C00051
MCTRL: Actual speed value 24524 5FCC E 1 INTEGER_32 1 ;
C00052
Motor voltage 24523 5FCB E 1 UNSIGNED_16 1 ;
C00053
DC-bus voltage 24522 5FCA E 1 UNSIGNED_16 1 ;
C00054
Motor current 24521 5FC9 E 1 UNSIGNED_16 100 ;
C00056
Torque 24519 5FC7 A 2 INTEGER_32 100 ;
C00057
Maximum torque 24518 5FC6 E 1 UNSIGNED_32 100 ;
C00058
Output frequency 24517 5FC5 E 1 INTEGER_32 100 ;
C00059
Appl.: Reference frequency C11 24516 5FC4 E 1 UNSIGNED_32 100 ;
C00061
Heatsink temperature 24514 5FC2 E 1 INTEGER_16 1 ;
C00064
Device utilisation (Ixt) 24511 5FBF A 3 INTEGER_16 100 ;
C00066
Thermal motor load (I²xt) 24509 5FBD E 1 INTEGER_16 100 ;
C00073
Vp Imax controller 24502 5FB6 E 1 UNSIGNED_16 100 ;;
C00074
Ti Imax controller 24501 5FB5 E 1 UNSIGNED_16 1 ;;
C00081
Rated motor power 24494 5FAE E 1 UNSIGNED_16 100 ;;
C00084
Motor stator resistance 24491 5FAB E 1 UNSIGNED_32 1 ;;
C00085
Motor stator leakage inductance 24490 5FAA E 1 UNSIGNED_16 100 ;;
C00087
Rated motor speed 24488 5FA8 E 1 UNSIGNED_16 1 ;;
C00088
Rated motor current 24487 5FA7 E 1 UNSIGNED_16 100 ;;
C00089
Rated motor frequency 24486 5FA6 E 1 UNSIGNED_16 1 ;;
C00090
Rated motor voltage 24485 5FA5 E 1 UNSIGNED_16 1 ;;
C00091
Motor cosine phi 24484 5FA4 E 1 UNSIGNED_8 100 ;;
C00092
Motor magnetizing inductance 24483 5FA3 E 1 UNSIGNED_16 10 ;;
C00093
Power section ID 24482 5FA2 E 1 UNSIGNED_16 1 ;
C00094
Password 24481 5FA1 E 1 INTEGER_32 1 ;;
C00095
Motor magnetising current 24480 5FA0 E 1 UNSIGNED_16 100 ;
C00097
Rated motor torque 24478 5F9E E 1 UNSIGNED_32 100 ;
C00098
Rated device current 24477 5F9D E 1 UNSIGNED_16 10 ;
C00099
Firmware version 24476 5F9C E 1 VISIBLE_STRING ;
C00100
Firmware version 24475 5F9B A 4 UNSIGNED_8 1 ;
C00105
Deceleration time - quick stop 24470 5F96 E 1 UNSIGNED_32 1000 ;;
C00106
Auto-DCB: hold time 24469 5F95 E 1 UNSIGNED_32 1000 ;;
C00107
DCB: hold time 24468 5F94 E 1 UNSIGNED_32 1000 ;;
C00114
DIx inversion 24461 5F8D E 1 UNSIGNED_16 ;;
C00118
DOx inversion 24457 5F89 E 1 UNSIGNED_8 ;;
C00120
Motor overload threshold (I²xt) 24455 5F87 E 1 INTEGER_16 100 ;;
C00123
Device utilisat. threshold (Ixt) 24452 5F84 E 1 INTEGER_16 100 ;;
C00134
Ramp rounding - main setpoint 24441 5F79 E 1 UNSIGNED_8 1 ;;
C00137
Device state 24438 5F76 E 1 UNSIGNED_16 1 ;
C00141
Device settings 24434 5F72 A 1 UNSIGNED_8 1 ;;
C00142
Auto-start option 24433 5F71 E 1 UNSIGNED_8 ;;
C00144
Switching freq. reduct. (temp.) 24431 5F6F E 1 UNSIGNED_8 1 ;;
C00150
Status word 24425 5F69 E 1 UNSIGNED_16 ;
C00155
Status word 2 24420 5F64 E 1 UNSIGNED_16 ;
Code Name Index Data Access
dec hex DS DA DT Factor R W CINH