MERLIN LEGEND Communications System Release 6.1
System Programming Guide
555-661-111
Issue 1
August 1998
Programming Procedures
Page 3-39System Renumbering
3
Direct Station Selector (DSS) Page Buttons 3
Use this procedure to set the three Page buttons on the DSS to correspond to the
system numbering plan. This procedure assigns extension numbers to DSS
buttons. You cannot program individual buttons on a DSS; this is the only method
for programming DSS buttons.
Page button assignment should be sequential. If only one DSS is attached, each
Page button assignment sets the console for a range of 50 extension numbers:
Page 1: 0 to 49; Page 2: 50 to 99; Page 3: 100 to 149.
If two DSSs are attached, each Page button assignment sets the console for a
range of 100 extension numbers. If two DSSs are attached to the console, change
the factory setting so that the difference between extension numbers assigned to
the range is at least 100. For example, assign Page 1 to begin with extension 10,
Page 2 to begin with extension 110, and Page 3 to begin with extension 210.
Operator Park Zone codes must be included in the extension number range
specified for one of the Page buttons.
!
CAUTION:
!
CAUTION:
Select
(YJU
on the console, or


on the PC, when you have finished this
procedure. If you press Home, extensions may remain in the forced idle
condition (the LED next to each DSS button is on), and the system may
have to be restarted.
Summary: Assign Direct Station Selector
Page Buttons 3
Programmable by System Manager
Mode All
Idle Condition Not required
Planning Form Form 6a, Optional Operator Features
Factory Setting Page 1=0; Page 2=50; Page 3=100
Valid Entries 1, 2, 3
Inspect Yes
Copy Option No
Console Procedure
6\V5HQXPEHU→6LQJOH→More→'66%XWWRQV→Dial page
no.
→(QWHU→Dial first ext. no.→(QWHU→([LW→([LW
PC Procedure

→→→→Type page no.→→
Type first ext. no.→→→

Table of Contents

Other manuals for Lucent Technologies MERLIN LEGEND Release 6.1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lucent Technologies MERLIN LEGEND Release 6.1 and is the answer not in the manual?

Lucent Technologies MERLIN LEGEND Release 6.1 Specifications

General IconGeneral
BrandLucent Technologies
ModelMERLIN LEGEND Release 6.1
CategoryConference System
LanguageEnglish

Related product manuals