MERLIN LEGEND Communications System Release 6.1
System Programming Guide
555-661-111
Issue 1
August 1998
Programming with SPM
Page 2-32Using SPM
2
The Inspect function (
) lets you see which modules have been assigned to
slots on the control unit. Note that both phantom boards and real boards display if
you use the Inspect function. Table 2–5
shows the type of boards that you can
select. To see only real board assignments, you must print the System Information
report:
6\VWHP→More→3ULQW→6\V6HWXS
Table 2–5. Board Types
Board Type Description
/65
4 loop-start line jacks with 4 touch-tone receivers
*/5
4 ground-start/loop-start line jacks with 4 touch-tone receivers
/6
8 loop-start line jacks
*/,'
8 ground-start/loop-start line jacks with Caller ID capability
available on the loop-start lines and 2 touch-tone receivers
*/6
8 ground-start/loop-start line jacks
/6$
4 loop-start line jacks and 8 ATL analog extension jacks
*/$
4 ground-start/loop-start line jacks and 8 ATL analog extension
jacks
*/0
4 ground-start/loop-start line jacks and 8 MLX extension jacks
(16 endpoints)
$7/
8 analog extension jacks
0/;
8 MLX-20L extension jacks (16 endpoints)
75237
12 tip/ring extension jacks with 2 touch-tone receivers or 008
OPT jacks
755
16 tip/ring extension jacks with 4 touch-tone receivers
','
8 DID trunk jacks with 2 touch-tone receivers
(0
4 E&M tie trunk jacks
'
1 DS1 jack (24 channels)
%5,
8 BRI trunk jacks (16 channels)