Programming Procedures
Page 3-340Optional Extension Features
3
Delayed Call Forwarding 3
Delayed Call Forwarding allows a user to answer or screen a call arriving at an
extension before the call is forwarded through Call Forwarding, Remote Call
Forwarding, or Follow Me. The forwarding delay is the number of rings before the
call is forwarded. This delay can range from 0 to 9 rings. If the forwarding delay is
set to 0, the call is forwarded immediately. Delayed Call Forwarding is available
only in Release 4.0 and later.
NOTE:NOTE:NOTE:
When Do Not Disturb is activated at an extension, it overrides Delayed Call
Forwarding and the call is forwarded immediately.
Use this procedure to assign or remove Delayed Call Forwarding from an
extension. If you are assigning Delayed Call Forwarding to a group of sequential
extensions, begin by programming the lowest extension number to take
advantage of the
1H[W screen key (see “Standard Procedures”).
Summary: Delayed Call Forwarding 3
Programmable by System Manager
Mode All
Idle Condition Not required
Planning Form Form 4b, Analog Multiline Telephone
Form 4d, MLX Telephone
Form 4e, MFM Adjunct: MLX Telephone
Form 4f, Tip/Ring Equipment
Form 5a, Direct-Line Console (DLC): Analog
Form 5b, Direct-Line Console (DLC): Digital
Form 5c, MFM Adjunct: DLC
Form 5d, Queued Call Console (QCC)
Data Form 1a, Modem Data Workstation
Data Form 1b, ISDN Terminal Adapter Data Workstation
Factory Setting 0 rings
Valid Entries 0 - 9 rings
Inspect Yes
Copy Option No
Console Procedure
([WHQVLRQVMore'HOD\)UZGDial ext. no.
(QWHUDropDial no. of delay rings(QWHU
([LW
([LW
PC Procedure
Type ext. no.7
+
Type no. of delay rings

Table of Contents

Other manuals for Lucent Technologies MERLIN LEGEND Release 6.1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lucent Technologies MERLIN LEGEND Release 6.1 and is the answer not in the manual?

Lucent Technologies MERLIN LEGEND Release 6.1 Specifications

General IconGeneral
BrandLucent Technologies
ModelMERLIN LEGEND Release 6.1
CategoryConference System
LanguageEnglish

Related product manuals