MERLIN LEGEND Communications System Release 6.1
System Programming Guide
555-661-111
Issue 1
August 1998
Programming Procedures
Page 3-429Optional Group Calling Features
3
A calling group or the QCC queue (Hybrid/PBX only) can provide overflow
coverage for more than one calling group; however, which group’s calls go to an
available member in the overflow calling group is unpredictable.
The factory-set extension number for the QCC Listed Directory Number is 800.
Summary: Group Calling Overflow and
Thresholds 3
Programmable by System Manager
Mode All
Idle Condition Not required
Planning Form Form 7d, Group Calling
Factory Setting Overflow coverage: none
Threshold: 1 call
Timeout: 0 sec
Prompt-based overflow: Disabled
Valid Entries Overflow coverage: Backup extension number
Threshold: 1 to 99 calls
Timeout: 0 to 900 seconds
Prompt-based overflow: Enabled, Disabled
Inspect No
Copy Option No
Console Procedure
([WHQVLRQV→More→*US&DOOLQJ→2YHUIORZ→
Dial calling group ext. no.→(QWHU→Dial overflow ext. no.→
(QWHU→1XPEHU%DVHG2YHUIORZ→Drop→Dial no. of
calls
→(QWHU→7LPH%DVHG2YHUIORZ→Drop→
Dial no. of seconds→(QWHU→3URPSW%DVHG2YHUIORZ→
<HVor1R→(QWHU→([LW→([LW→([LW
PC Procedure

→→→→Type calling group ext. no.→
→Type overflow ext. no.→→→7
+
I→Type
no. of calls
→→→7
+
I→Type no. of seconds→
→→ or →→→→