MERLIN LEGEND Communications System Release 6.1
System Programming Guide
555-661-111
Issue 1
August 1998
Programming Procedures
Page 3-429Optional Group Calling Features
3
A calling group or the QCC queue (Hybrid/PBX only) can provide overflow
coverage for more than one calling group; however, which group’s calls go to an
available member in the overflow calling group is unpredictable.
The factory-set extension number for the QCC Listed Directory Number is 800.
Summary: Group Calling Overflow and
Thresholds 3
Programmable by System Manager
Mode All
Idle Condition Not required
Planning Form Form 7d, Group Calling
Factory Setting Overflow coverage: none
Threshold: 1 call
Timeout: 0 sec
Prompt-based overflow: Disabled
Valid Entries Overflow coverage: Backup extension number
Threshold: 1 to 99 calls
Timeout: 0 to 900 seconds
Prompt-based overflow: Enabled, Disabled
Inspect No
Copy Option No
Console Procedure
([WHQVLRQV→More→*US&DOOLQJ→2YHUIORZ→
Dial calling group ext. no.→(QWHU→Dial overflow ext. no.→
(QWHU→1XPEHU%DVHG2YHUIORZ→Drop→Dial no. of
calls
→(QWHU→7LPH%DVHG2YHUIORZ→Drop→
Dial no. of seconds→(QWHU→3URPSW%DVHG2YHUIORZ→
<HVor1R→(QWHU→([LW→([LW→([LW
PC Procedure

→→→→Type calling group ext. no.→
→Type overflow ext. no.→→→7
+
I→Type
no. of calls
→→→7
+
I→Type no. of seconds→
→→ or →→→→

Table of Contents

Other manuals for Lucent Technologies MERLIN LEGEND Release 6.1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lucent Technologies MERLIN LEGEND Release 6.1 and is the answer not in the manual?

Lucent Technologies MERLIN LEGEND Release 6.1 Specifications

General IconGeneral
BrandLucent Technologies
ModelMERLIN LEGEND Release 6.1
CategoryConference System
LanguageEnglish

Related product manuals