Programming Procedures
Page 3-532Automatic Route Selection
3
ARS Tables 3
Use this procedure for the following tasks:
â–  To specify type of table (6-digit, area code, exchange,
or 1 + 7-digit number)
â–  To add or change area codes to be included in each table
â–  To add or change exchanges to be included in each table
A maximum of 16 tables can be established, numbered 1 through 16. Each table
can have a maximum of 100 entries, numbered 1 through 100. Tables 17 and 18,
the Default Toll and Default Local tables respectively, cannot be changed.
The first entry in a 6-digit table must be the area code. Subsequent entries consist
of exchanges within that area code.
Area code tables can contain only area codes. In Release 6.0 and later systems,
these tables are often used to provide cost-efficient calling through private
network lines/trunks connected to another system. The type of table required
depends upon how users in the networked systems will employ networked lines.
When you use ARS in this way, the ARS access code is only permitted on private
trunks and is blocked from calls that arrive from the public switched network.
Exchange and 1 + 7-digit tables can contain only exchanges.
The wildcard character (Pause) cannot be used to enter area codes or exchanges
in ARS tables.
Summary: ARS Tables 3
Programmable by System Manager
Mode Hybrid/PBX
Idle Condition Not required
Planning Form Form 3f, Automatic Route Selection Tables
Factory Setting Not applicable
Valid Entries Not applicable
Inspect Yes
Copy Option No
Console Procedure
7DEOHV→$56→$56,QSXW→Dial table no.→(QWHU→
Specify table type→(QWHU→Dial entry no.→(QWHU→
Drop
→Dial no.→(QWHU→([LW→([LW
PC Procedure

→→→Type table no.→→Select table type→
→Type entry no.→→7
+
→Type no.→
→→

Table of Contents

Other manuals for Lucent Technologies MERLIN LEGEND Release 6.1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lucent Technologies MERLIN LEGEND Release 6.1 and is the answer not in the manual?

Lucent Technologies MERLIN LEGEND Release 6.1 Specifications

General IconGeneral
BrandLucent Technologies
ModelMERLIN LEGEND Release 6.1
CategoryConference System
LanguageEnglish

Related product manuals