Maintenance work on the superstructure
8.9 Hydraulic system
8 - 72 3 302 719 en Maintenance manual
GMK6300L-1
13.02.2018
There is a gauge port (1) on the pump (2).
When a hydraulic function is run, e.g.
tilting
the crane cab
, oil can then be taken at the
gauge port.
Taking oil samples
Clean the gauge port and connect the hose (1)
to the pump (3);
à Connecting the hose,
p. 7 - 87.
Put the hose end (2) into the receptacle (4).
Start the engine.
Tilt the crane cab.
Allow 2 litres (0.5 gal) of oil to flow into
the receptacle.
Switch the engine off and put the hose
end (2) into the sample container (5).
Start the engine.
Tilt the crane cab.
Allow 0.3 litres (0.08 gal) of oil to flow
into the sample container.
Switch off the engine.
Remove the hose; à Disconnecting the hose, p. 7 - 88.
Seal the sample container and dispatch it; à Dispatch the oil sample to the
laboratory
, p. 7 - 89.
Determine the quality of the oil; à Determining the quality of the oil,
p. 7 - 89.