- 60 -
The REQUEST form defines the external device data request parameters.
• I
NIT. STRING: enter the initialising string required to activate communications with
the device. Merlin only sends the string, the first time it communicates, with the
device (each time the device is switched on); the virtual keyboard includes a
list of all ASCII characters, complete with control characters. Tap “fx” to access.
• S
INGLE MEASURE: option YES, NO. This feature optimizes the management of
serial devices with long acquisition time, avoiding to repeat the request more
than once.
• I
NTER REQUEST TIME: delay time between 2 measure requests to a serial gauge.
• B
Y STRING: specify the prefix, the suffix and, whether or not the ID input should
be sent
• B
Y SIGNAL (DTR): protocol requests by DTR signal; specify the duration in second.
• N
ONE: no request; in this case the device sends the measurement data auto-
nomously.
• RJ-201
AND RJ-210: For some devices, the request is too complex so it has
been developed a specific field, to be selected. The software will manage
automatically a configuration.