EasyManua.ls Logo

Maytag MDE25PN - Diagnostic Mode; Dryer Help Mode

Maytag MDE25PN
118 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6-15
This mode is entered by depressing
DELICATES for one second while in set-up
code 6 (or while dAS displays if operating
with Maytag Data Acquisition setup) or with
a diagnostic code present. Diagnostic codes
are cleared on entry and all display segments
should ash. If a diagnostic code persists, it
must be corrected before the diagnostic cycle
may be executed.
There are 2 procedures to initiate cycle activity
from diagnostic mode for these models:
Dryer Field Diagnostic Cycle – With the
entire display flashing, the cycle is started
by pressing the PERM. PRESS button.
The cycle consists of 7 minutes of heat
and 1 minute of cool down. The WHITES
AND COLORS button will increment the
diagnostic cycle minutes up to 99, then roll
over to 2 minutes. Pressing the DELICATES
button will cancel this cycle and exit the
diagnostic mode.
1.

Dryer help mode is entered by pressing the
WHITES & COLORS button while in set-up
option 2.XX (or while dAS displays if operating
with Maytag Data Acquisition setup). In help
mode, the software revision is displayed in the
digits. Press the WHITES & COLORS button
at any time to exit help mode.

 
71 Generation 2 debit card cycle
polling message out of sequence.
74 Generation 2 debit card remaining
balance message out of sequence.
75 Generation 2 debit card new card
balance message out of sequence.
88 Invalid messaging state
found in da communications
comm_suprv () routine
In the Help Mode, other display symbols
and elements are used to reect the state of
various inputs and outputs as follows:
* ........................................low voltage present
° (symbol above digit) ....................door closed
OR .................................motor sensed running
AIR ...........................heater/gas valve relay on
FLUFF .......................................motor relay on


Table of Contents