EasyManua.ls Logo

Maytag MDE25PN - Remove Blower Housing; Remove Broken Belt Switch

Maytag MDE25PN
118 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4-25
Remove blower wheel (See page 4-23).
Remove wire connectors from thermistor
and thermal fuse (See page 4-24).
Remove the short 1/4” hex head screw that
secures blower housing to the exhaust duct.
Remove three 1/4” hex head screws from
inside the blower housing that secure it to
the motor bracket.
1.
2.
3.
4.


Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
Three 1/4” Hex
Head Screws
1/4” Hex
Head Screw
Four Wire
Connectors
Remove dryer drum (See page 4-22).
Remove 2 star head screws from back of
motor bracket.
Remove two wire connectors and remove
broken belt switch switch.
1.
2.
3.


2 Star Head
Screws
Electrical Shock Hazard
Disconnect power before servicing.
Failure to do so can result in death or
electrical shock.
Replace all parts and panels before
operating.

Table of Contents