3-2
Room temperature air (white arrows) enters
the lower portion of the dryer through a gap
formed behind the bottom of the lower front
panel. Therefore it is very important to raise
the bottom of the dryer by installing the feet
properly. This room air is drawn though
the heating system (gas burner or electric
element).
Heated dry air (dark arrows) is then drawn
up the heat duct mounted behind the rear
bulkhead and then into the drum.
As the dry heated air circulates in the drum it
picks up moisture from the wet clothes. The
more space around tumbling clothes for dry
heated air to come into contact with fabric, the
faster clothes will dry.
The moistened heated air is drawn down
through the lint filter, through the blower and
into the exhaust duct, where it is vented out of
the dryer and out of the building.
Static Pressure Single unit exhaust, 10.2 cm(4" ) round r
10.2 cm (4") rigid duct
Thermo-protected against overload auto-reset 1/3 HP, 240 Volt, 50 Hz
USA 240
Requires 193 sq cm per dryer pocket
• Single port burner 20,000 BTU/hr.
3-2
air inTakE
an
D ExHauST
Room temperature air (white arrows) enters
the lower portion of the dryer through a gap
formed behind the bottom of the lower front
panel.
Therefore it is very important to raise
the bottom of the dryer by installing the feet
properly. This room air is drawn though
the heating system (gas burner or electric
element).
Heated dry air (dark arrows) is then drawn
up the heat duct mounted behind the rear
bulkhead and then into the drum.
As the dry heated air circulates in the drum it
picks up moisture from the wet clothes. The
more space around tumbling clothes for dry
heated air to come into contact with fabric, the
faster clothes will dry.
igid duct.
with the dryer for additional information)
nstructions provided
Electri
*****##@!@!!@#$%^&*><?><?|\
v, 4600
than 0" water column.
Capacity
190 One washer load is a full dryer load
Motor
Air Flow
Tumbler Revolution per minute
50 RPM ± 1.5
Rotation Drum Turning, when viewed from the front Clockwise
Heat Source
• c
• watts, 30 amp fuse
• Gas
direct ignition, automatic shut-off
Exhaust Venting size
(See installation i
Makeup Air Free opening
Should not exceed 0.92" or be less
The moistened heated air is drawn down
through the lint filter
, through the blower and
into the exhaust duct, where it is vented out of
the dryer and out of the building.
5250 watts (240 v) / 4100 watts (208 v)
5550 watts (240 v) / 4600 watts (208 v)
S
EGATTAWNOITPIRCSED
r
etingituohtiwmumixaM053reyrDsaG
Igniter
(
NOTE: Ohm room temperature 180-400)
6
00
Electric Dryer USA / Canada
Heating Element USA / Canada
Cubic feet per minute exhausted from dryer
6.1m/m³ Electric 6.5 m/m³ Gas
L iters