CAUTION: If the gauge does not slide in easily, do not force it. You may scratch the highly pol-
ished surface of the hook support or hook basket, resulting in thread breaks.
Figure 5 – Retaining Finger Gauge Usage
The retaining nger gauge should slide between the hook support and hook basket with no resis-
tance. The gap between the hook support and hook basket should be no more than 1.1 times the
thickness of the gauge. (The gauge is 0.020” and the tolerance is ± 0.002”.)
8. The tip of the hook support should be ush with the top of the hook basket.
9. If the adjustment is not correct, continue to the Adjustment Procedure below.
Adjustment Procedure
Note: Prior to adjustment, be sure to follow steps 1 through 9 in the Rotary Hook Support
Inspection Procedure above.
1. Use the 2mm Allen wrench to loosen the 2 screws holding the hook support.
Figure 1 – Hook Support Screws
2. Position the hook support in the notch at the top of the rotary hook basket.
Figure 2 – Rotary Hook Basket Notch
3. Insert the gauge between the hook support and hook basket.