145 of 271
9. Reconnect the thread tubes to the back of the thread feeder assembly in the correct numerical
order from right to left (as you face the front of the needlecase).
10. Reinstall the needlecase cover.
11. Replace the needlecase access cover to the needle case assembly.
•
IMPORTANT! Verify needle depth and hook timing anytime you reinstall the needle case!
12. Complete any remaining work you have left on the machine, then turn the machine back on. To
do so, disengage the emergency stop (if it is engaged) by twisting in the direction of the arrows
until the red button pops out and turn the main power switch ON.
13. Verify needle depth and hook timing.