EasyManua.ls Logo

MICRO-EPSILON ILD 1420-10 - Page 28

Default Icon
122 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 28
Installation
optoNCDT 1420
Keep this area free from
other light sources and/or
their reflections
Limits for free
space
Laser beam
10
(.39)
3
(.12)
A
SMRRange
30 (1.18)
20 (.79)
8
(.31)
7.50
(.3)
46 (1.81)
40 (1.57)
8
(.31)
2.70
(.11)
2
(.08)
Y
6
(.24)
ILD 1420- 10 25 50 100 200 500
MR mm 10 25 50 100 200 500
SMR mm 20 25 35 50 60 100
EMR mm 30 50 85 150 260 600
Y mm 10 21 28 46 70 190
The indicated free space in the reception
area, see Fig. 13, has to be kept clear
from foreign objects and extraneous light
of other laser sensors at least until the end
of measuring range.
MR = Measuring range
SMR = Start of measuring range
MR = Midrange
EMR = End of measuring range
FSO = Full scale output
Fig. 13 Dimensional drawing and free space for optics
47,5
14
M12
A: 2x M3 for direct fastening or
2x M2 for bolt connection
Fig. 14 Dimensional drawing M12 cable connector

Table of Contents