2-4 Microtek User's Guide for Windows
Installation
• Release the carriage
• Set the SCSI ID
• Install interface card and connect scanner
• Use a terminator
Releasing the carriage
Your scanner has a locking screw at the bottom to protect the
scanner carriage mechanism during shipping. Before you operate
the scanner, you need to disengage the locking screw.
Unlocking models with a screw-type lock
(ScanMaker IIG, IISP/IISPX, and III)
1 With the scanner turned off, turn the scanner on its side to see
the locking screw at the bottom.
2 Using a screwdriver, turn the locking screw counterclockwise
to unlock it. When unlocked successfully, the screw will push
out a little, becoming nearly even with the bottom of the
scanner.
You can check the lock’s status by pushing on the screw cap.
If the screw springs back, the scanner is ready for scanning.
Turn screw
counterclockwise
Unlocking the ScanMaker III
Unlocking the ScanMaker IIG
and IISP/IISPX